Instructor
Tarek Tolba
ENGINEER
About me
TAREK TOLBA
MECHANICAL ENGINEER
Senior Technical Office Engineer (Orascom Construction)
35 YEARS OLD
o HVAC
- Read and understand architectural Drawing
- Project data collection ( orientation – elevation – walls exposure – floor area – no. of
people – lighting load – electrical equipment's load – widows )
- Load Estimation by ( Quick sizing (ASHRAE) - HAP software – Revit )
- Make a report Include ( total coil load – sensible coil load – cfm – entering db/wb
temp – outdoor ventilation )
- Use HAP report to make unit selection{ DX system (Decorative , Concealed ,
Packaged) – Chilled water system ( air cold chiller – water cold chiller) }
- selection for (FCU – AHU) Depending on Cooling Capacity , CFM , gpm
- selection for Cooling tower
- selection for PUMP Depending on gpm , Pressure Drop
- selection for HOOKUP of all systems .
- Air outlet selection ( square – round – linear bar – linear slot – jet diffuser )
Depending on
- ( total air flow rate – no. of supply – no. of return – position – NC – air throw –
pressure drop )
- Duct systems design (rectangular – round) By Mcquay Duct Sizer Depending on (air
flow rat – duct fitting – accessories )
- External Static presser calculation
- Design Drawings ( Autocad – Revit)
- BOQ & Specifications
o FIRE FIGHTING
- Make Fire Fighting System For Any Building according to Occupancy Hazard
(NFPA)
- Automatic (Sprinklers system – co2 / FM200 system)
- Manual ( Potable – F.H.C – F.H – F.D.C)
- piping & sizing for fire pipes
- selection for valves ( floor control valve – os&y – air vent – drain – relief valve )
- fire pump calculation (pressure – flow rat ) using fire elite hydraulic calculation program
- design drawings ( Autocad – Revit)
o PLUMBING
- WATER SUPPLY SYSTEM
- Checking the existing / Tie-in point for water supply network which supplying the
project.
- Calculate total fixture units for the project from IBC
- Calculate the required water tank volume (under ground – roof )
- Design (lifting – booster) water pump ( Q & pressure )
- Pipe sizing for riser & horizontal pipes
- pipe testing
- Valves selection for water supply network
- Design Drawings ( Autocad – Revit)
- DRAINAGE SYSTEM
- Pipe sizing for (Soil stack – waste stack – vent stack – Building sewer-rain water stack
- HVAC condensate)
- Piping installation , slope
- Clean out sizing
- Sizing and selection for I.C , Manhole , Catch basin
- Lifting station design
- Selection for submersible pump (flow rate – pressure)
- Pipe testing