
Explore how generation uses synchronous generators, step-up transformers, and transmission lines to deliver power at high voltage from 10–30 kV to 110–765 kV before distribution.
Explore the distribution stage of electric power, featuring step-down transformers, three-phase transmission, overhead and underground cables, and residential, commercial, and industrial loads.
Explore active (real) power, apparent power, and reactive power in power systems, and how voltage, current, and impedance angle determine the power factor and unity, lagging, or leading conditions.
Understand complex power and the power triangle to relate active, reactive, and apparent power in AC loads, using phasor form, voltage, current, and power factor angle.
Calculate the power factor, active power, and reactive power for a 12 kVA load at 120 V with a lagging 0.856 power factor, and derive current, impedance, and peak current.
Explore how inductive loads like motors affect power factor. Learn how power factor correction reduces reactive power, current, losses, and voltage drop to improve efficiency.
Improve power factor by placing a shunt capacitor in parallel with an inductive load, injecting negative reactive power to approach unity, and review the power triangle before and after.
Explain power factor correction for a 4 kW inductive load at 120 V and 60 Hz, improving from 0.8 lagging to 0.95 using a 310.4 μF capacitor and 1.684 kVAr.
Explain complex power flow between two ideal sources on a transmission line and compute S12, P12, and Q12 from V1, V2, deltas, and reactance X, assuming zero resistance.
Two sources connect via a line of 1 plus j7 ohms impedance. Active power flows v2 to v1; reactive power flows v1 to v2; losses 9.8 w.
Explore how three phase circuits generate, transmit, and distribute power with three out-of-phase sources, and learn advantages like economy, reduced wiring, and constant instantaneous power for machines.
Explore how balanced three-phase supply delivers three equal-amplitude voltages 120 degrees apart, generated by a rotating magnetic field in a three-phase generator with stator windings arranged 120 degrees apart.
Explore the four possible three-phase connections: star, delta, star-delta, and delta-star, along with balanced loads, impedances, and star-delta transformations for four- and three-wire systems.
Relate line voltages to phase voltages in a balanced three-phase star system; line voltages have magnitude root three times the phase voltages and lead by 30 degrees.
Explore the balanced four-wire star-star three-phase system, deriving line currents from phase voltages, and show neutral current sums to zero, enabling neutral conductor removal.
Explore the balanced star-star 3-wire system, removing neutral, and analyze with a single-phase equivalent circuit to compute load phase and line currents and voltages.
Compute line currents ib and ic for a balanced three-wire system using a single-phase equivalent circuit, deriving van, vbn, vcn and line voltages from z store and z transmission line.
This lecture explains delta-connected loads, showing line currents have magnitude root three times phase currents and lag by 30 degrees, while line voltages lead phase voltages.
Explains analyzing a balanced star-delta system by converting delta loads to star and deriving a single-phase equivalent circuit to obtain line and phase currents and voltages.
Analyze the star-delta connection, convert the delta load to a star, form the per-phase circuit, and determine line and phase currents along with Vab, Vbc, and Vca.
Demonstrate converting delta supply to a star supply, obtain the neutral point, and determine phase and line voltages and currents in a balanced delta-star system.
Explore delta-to-star conversion and derive single-phase equivalents to compute line currents, phase voltages, and line voltages for a delta-connected power system.
Examine balanced delta-delta connections in three-phase power systems, converting delta to star, modeling the load as Z delta over three, and deriving line and phase currents and voltages.
A delta-delta example analyzes a three-phase delta system, derives z star = 4 + 3j, and shows load line voltage equals supply when line impedance is zero.
Demonstrate that instantaneous power is constant in balanced three-phase systems, derive p_inst = 3 V_b I_b cos theta, and relate phase voltages and currents in inductive loads.
Learn to calculate active, reactive, and complex power in balanced three-phase circuits for star and delta loads, using phase and line voltages and currents, including impedance-based formulas.
Improve the power factor of three-phase circuits by using a parallel capacitor bank to supply reactive power, with star or delta connections and guidance on calculating required capacitance.
Analyze power factor correction in balanced three-phase circuits by evaluating parallel loads, calculating complex power and line currents, and configuring a delta-connected capacitor bank to reach 0.9 lagging.
Learn how synchronous generators (alternators) convert mechanical power from turbines into three-phase electric power using a stator and rotor with a field winding, and how frequency depends on speed.
Compare salient pole and cylindrical rotor synchronous generators, showing how salient poles provide multiple poles at low speeds for hydroelectric turbines, while cylindrical rotors use few poles at high speeds.
Explore how a synchronous generator converts mechanical power to electric power via electromagnetic induction, using a rotating magnetic field to cut armature windings and produce balanced three-phase voltages.
Derive the induced EMF equation for the armature winding of a three-phase synchronous generator from Faraday’s law, considering rotating flux and winding factor.
Explain how the induced emf in a synchronous generator scales with speed and flux, and how field current shapes the magnetization curve, including open circuit characteristics and residual flux.
Develop a per-phase equivalent circuit for a synchronous generator, linking field and armature circuits and using Xs to relate the internal emf E to the terminal voltage V phase.
Explore the phasor diagram of a synchronous generator, deriving armature voltage E from the load phase voltage V phase using KVL, and compare lagging, unity, and leading power factors.
Explain how a synchronous generator converts mechanical power from a prime mover into electrical power using a power flow diagram, detailing losses, developed power, efficiency, and voltage regulation.
Explore how the power angle characteristics link output power to the torque angle delta in a synchronous generator, highlighting stable operation and practical delta around 20–30 degrees under governor control.
Explores a three-phase synchronous generator connected to the grid. Computes excitation voltage e, armature current ia, and power angle delta, and determines maximum power to the infinite bus.
Analyze a 13.8 kV, 50 MVA, 0.9 pf lagging, four-pole synchronous generator using its equivalent circuit to determine synchronous speed, armature voltage, losses, input power, torque, efficiency, and voltage regulation.
Explore how transformers transfer ac power from primary to secondary windings through magnetic flux in an iron core, enabling voltage step up or down via turns ratio.
Revises the real transformer equivalent circuit, highlighting copper losses (R1, R2), core losses (RC, XM), leakage flux, and primary and secondary leakage reactances (X1, X2).
Analyze a single-phase transformer using the approximate equivalent circuit referred to the primary, and determine the turns ratio, load-reflected values, supply voltage, no-load current, and supply current.
The short circuit test on transformers applies reduced primary voltage with the secondary shorted to measure short-circuit current, voltage, and copper losses, and to derive R_eq and X_eq.
Determine transformer parameters from open circuit and short circuit tests on a 15 kVA 440/230 v transformer, including rc, xm, r_eq, x_eq, and z_eq.
derive transformer performance from the primary-referred equivalent circuit, and analyze efficiency, loading ratio, copper and core losses, and voltage regulation.
Learn the construction and configurations of three-phase transformers, from three identical single-phase units forming a bank with star or delta connections to a compact single-core, three-limb design with six windings.
Explore the four three-phase transformer connections—star-star, star-delta, delta-star, and delta-delta. Understand their advantages, drawbacks, and typical uses—from substation and transmission to distribution—highlighting third harmonic behavior and open delta (V) configurations.
Learn the per phase model of a three-phase transformer, derive turns ratios for delta-star configurations, and simplify power transformers to a per phase circuit with a single reactance.
Calculate the efficiency of a practical three-phase transformer at 80% full load and 0.7 pf, then find maximum efficiency near loading X equals 0.33 by balancing core and copper losses.
Examine how transmission lines transfer power from generators to the distribution network, using high voltage to reduce losses, and compare overhead three-phase lines with underground cables and their key components.
Explore the four transmission line parameters—series resistance, series inductance, and shunt capacitance and conductance—per unit length in the distributed line model.
Explore transmission line modelling and two-port network representation using abcd parameters to assess voltage profiles, power flow, and losses, and evaluate line performance through efficiency and voltage regulation.
Explain short transmission line model for under 80 km lines, neglecting capacitance, represented by series resistance and inductive reactance Z; analyze voltage regulation for lagging, unity, and leading power factors.
Explain the short line model for a 220 kV, 40 km line to compute sending-end voltage and power, then assess voltage regulation and efficiency for lagging and leading 0.8 pf.
Explore the medium transmission line model, using half of the shunt capacitance at each end in a nominal bimodal (pi) two-port network, deriving ABCD constants.
Compute the sending end voltage and voltage regulation for a practical medium transmission line, deriving impedance and admittance and applying the two-port model with a and b.
Explore the long transmission line model with distributed per unit length parameters, derive voltage and current along the line using gamma, and obtain the abcd parameters and zc.
Derive the equivalent pi model for long transmission lines using z dash and y dash over two. Compare it with the nominal pi model using gamma and line length L.
Explain how lossless transmission lines neglect resistance and conductance, yielding a real surge impedance. Illustrate imaginary propagation constant and Ferranti effect, plus no-load and short-circuit voltage and current.
Explore surge impedance loading (SIL) as the power delivered to a lossless line loaded by its characteristic impedance, yielding a flat voltage profile and zero reactive power.
Calculate the ABCD parameters for a 320 km, 500 kV lossless transmission line, determine the characteristic and surge impedance loading, and illustrate long-line modeling with cosh and sinh.
Learn how the per unit system expresses electrical quantities as ratios to base quantities, enabling easier analysis of power networks, transformers, and per unit impedance diagrams.
Explore per unit calculations for voltage, current, and power, define base values, and apply per unit impedance, resistance, and reactance in single-phase and three-phase systems.
Compute base values and per-unit impedances for a three-phase, three-region power system with two transformers, enabling short-circuit, load-flow, and stability analyses.
Explore changing base to a common system base to update per unit impedances of generators and transformers, using the Z_pu,new formula with S_base and V_base values.
This lecture demonstrates a comprehensive numerical example of the per unit system, showing how a common base simplifies power-system analysis and calculations across a generator, transformers, lines, motor, and load.
Update per-unit impedances across generator, transformers, lines, load, and motor as system bases shift; demonstrate converting actual values to per-unit and back for a complete numerical example.
Perform load flow analysis on a power system to determine voltages, currents, active and reactive powers, and losses, using bus, line, and generator data to ensure balance and voltage stability.
Identify essential load-flow definitions: bus as a node, bus voltage v_i, and injected current i with i = i_gen − i_demand; p_i, q_e, v_i, delta v_i drive power flow analysis.
Classify power system buses into generator (bv) buses, load (bq) buses, and slack (swing) buses, and explain which quantities are known or unknown in load-flow analysis.
Explore the bus admittance matrix (Y bus) as the first step in load flow analysis. Learn how Y bus is formed from network admittances and its relation to Z bus.
Form the bus admittance matrix (Y bus) for a five-bus system from line data, converting impedances to admittances and accounting for line charging in the Y bus.
Learn how to derive the load flow equations from the bus admittance matrix, then apply nonlinear iterative methods such as Gauss–Seidel and Newton–Raphson, and use the linearized DC power flow.
Learn how the approximate method solves load flow without iteration, given pure reactive line impedances, small bus angles, and PV buses with a single slack bus, using the Y bus.
Solve a load flow problem using the approximate method on a three-bus system. Construct the y bus in polar form and build a bus table to determine voltages and injections.
Master the Gauss-Seidel method to solve load flow problems with iterative voltage updates for active and reactive power, bus types, and stopping criteria.
Use the Gauss-Seidel method to solve a 3-bus load-flow, building the y bus, updating voltages and angles, and determining line powers and system losses.
demonstrates a gauss-seidel load-flow update, performing a second iteration with a flat-start for v and delta, updating v2 and v3, and confirming convergence below 0.01 with voltages v2 0.972∠-2.56 and v3 1.04∠-0.402.
After solving the load flow, compute the line flows and losses for transmission lines. Use bus voltages and line impedances to determine active and reactive power flows and detect overloads.
Learn how the DC power flow method linearizes the AC load flow to quickly compute active power and voltage angles at the buses, while neglecting reactive power and losses.
Derive the DC power flow with fixed voltages and small angle differences, forming the B matrix from the Y bus to compute bus angles and line powers.
Explore a three bus dc power flow example to compute voltage angles and active line flows, compare dc power flow with gauss seidel, and highlight assumptions like neglecting reactive power.
Explore fault analysis in power systems, defining volt and short circuits, and compare balanced and unbalanced voltages. Learn how short-circuit currents drive switchgear design, circuit breakers, and relay settings.
Identify mechanical and electrical causes of faults in the power system, including conductor breakage causing open circuits, accidental phase connections causing short circuits, insulation degradation, over voltages, and operating errors.
Analyze yearly fault statistics across overhead lines, underground cables, generators, transformers, and switchgear to identify main causes, such as lightning, insulation failure, and overvoltages.
Identify open and short circuit faults. Explain open conductor and three-conductor faults, and symmetrical and unsymmetrical faults, including single line to ground and line to line fault types.
Explore the consequences of short circuit faults in power systems, including thermal heating, electrodynamic forces, and voltage drops, and learn how fast fault clearance preserves stability.
Assume no-load operation with bus voltages at one per unit and fault currents exceed load. Represent lines and transformers by reactances, and model generators with sub transient reactance and emf.
Hi and welcome everyone to our course "Ultimate Electrical Power System Engineering Masterclass"
In this course, you are going to learn everything about power system analysis starting from the power system basics and fundamentals of single phase and three phase electric systems moving to designing and modelling different power system components such as: generators, transformers, and transmission lines, ending with a complete power system studies such as load flow studies and power system faults analysis.
Thus, this course will be your complete guide in one of the main areas of power engineering: ( power system analysis )
The course is structured as follows:
Firstly, an overview on the power system structure is illustrated through the following topics:
Generation, transmission, distribution, and consumption of electric power
How to draw a single line diagram (SLD) of any power system
Then, the next topic will be about a review on basic electrical engineering concepts to be a quick refresh for you. The following topics will be covered:
Different types of powers in power system
Complex power, power triangle, and power factor definitions
power factor correction
Complex power flow in any power system
Then, a complete study of three phase systems is introduced since 99% of practical electric networks are actually three phase systems. Thus, three phase circuits are explained in depth through the following topics:
Why we need three phase systems?
Three phase supply and load
Different 3-ph connections (star-star), (star-delta), (delta-star), (delta-delta)
Difference between (3-wire) and (4-wire) 3-ph systems
The relations between line and phase currents and voltages
Power analysis in 3-ph systems
Power factor improvement in 3-ph circuits
Then, you are going to learn the modelling and characteristics of generators in power systems starting from the operation and construction of alternators moving to measuring the performance indices of synchronous generators. The following topics will be covered:
Construction and operation of alternators
Salient pole vs. Cylindrical rotor generators
Generator model in power systems
Generator phasor diagram and characteristics
Generator performance parameters
Power angle curve of synchronous generators
The next topic is about transformers and their use in power systems. We are going to discuss how the transformers work and their importance in power systems through the following outlines:
Construction and operation of transformers
Transformer equivalent circuit
Tests performed on transformers
Transformer efficiency and regulation
Three-phase transformer types and connections
Per phase model of three phase transformer
After that, we are going to a complete modelling of different types of transmission lines with assessing the transmission line performance in electric networks through the following topics:
Overhead lines vs. Under ground cables (UGC)
Transmission line modelling and performance
Short, medium, and long line models
Lossless transmission lines
Surge impedance loading (SIL)
Now, after modelling and analyzing different power system components, lets move to the per unit system and learn the concept and importance of per unit in power system analysis through the following outlines:
Concept of per unit
Per unit calculations
How to draw per unit reactance diagram
Change of base
Numerical examples on practical power systems
Then, we are going to a complete power flow analysis where we are going to know the electrical parameters for any power system under any operating conditions. The following topics are discussed
Concept and importance of power flow study
Definitions in power flow analysis
Types of power system buses
Formation of Ybus
Approximate method
Iterative methods for load flow analysis
Gauss-Seidal method
Power flows and losses analysis
DC power flow method
Numerical examples on practical power systems
Then, a complete fault analysis is performed on power systems to find the fault current, bus voltages and line current during the fault. All these outlines are discussed
Definition, causes, types, and consequences of electric faults
Complete symmetrical fault analysis using thevenin and Zbus
Symmetrical components and sequence networks
Complete unsymmetrical fault analysis using thevenin and Zbus
Finally, after the complete analysis of power system, practical projects are performed on MATLAB related to power systems as follows :
Project 1 - Stand alone synchronous Generator
Project 2 – Synchronous Generator connected to the grid
Project 3 - Simulation of 3-ph transformers
Project 4 - Transmission line design
Project 5 - Power flow study in MATLAB
Project 6 - Fault analysis in MATLAB
So, if you are Looking for a COMPREHENSIVE course about Electrical power system analysis engineering for power system modelling, design and analysis ?
If your answer is YES, then you're definitely in the right place.