Udemy
    •  
    •  
    •  
    •  
    •  
    •  
    •  
    •  
Turn what you know into an opportunity and reach millions around the world.
Learn More
Your cart is empty.
Keep shopping
Testing Commissioning SwitchGear
Rating: 4.4 out of 5(299 ratings)
1,279 students

Testing Commissioning SwitchGear

Reading Scheme of (ABB & Schneider) MV SwitchGear
Last updated 6/2024
Arabic
Arabic [Auto],

What you'll learn

  • An overview of electrical transmission substation.
  • Basic concepts about circuit breaker and Types of circuit breaker.
  • Why don't the distributor's switchgear have the same capacity ?
  • The importance of having a dc ac voltage inside the distributor cells
  • The main rules for reading the scheam of current circuits and the reasons that lead to their explosion.
  • Understand the general philosophy of closing, triping and interlock circuits.
  • What is the working theory of anti-pumping relay and anti slam ?
  • Importance of trip circuit supervision in the early detection of circuit breaker faults.
  • The most important modifications in the scheam before the distributor enters the service.
  • Introduction to 13.8KV ABB SwitchGear
  • The Importance of Automatic Capacitor Control Switch (ACCS)
  • The Importance of Automatic Changeover Switching Equipment ACSE
  • (Under Frequency & Under Voltage) Protection Panel
  • philosophy of High Impedance BusBar Protection Panel

Course content

4 sections31 lectures8h 35m total length
  • Introduction2:03
  • substation component7:26
  • components of electrical transmission substation.15:00
  • Classification of circuit breaker8:14
  • An overview of the distributor cells23:06
  • What is the difference between incomer feeder& bus coupler and outgoing feeder ?21:23
  • interview question

Requirements

  • Basic Electrical Engineering knowledge

Description

Dear fellows,

This is the most comprehensive online training of MV switchgear. Here you will learn all thing about MV Switchgears.

In an electric power system, switchgear is composed of electrical disconnect switches, fuses or circuit breakers used to control, protect and isolate electrical equipment. Switchgear is used both to de-energize equipment to allow work to be done and to clear faults downstream.


we will go through the following topics

  • An overview of electrical transmission substation.

  • Basic concepts about circuit breaker and Types of circuit breaker.

  • Compartments of MV SWGR

  • Current Transformer

  • Voltage Transformer

  • Earthing Switch

  • Two-position Switch

  • Protection Relay

  • Operations of MV SWGR

  • Mechanical interlocks of MV SWGR

  • CB Trolley components

  • CB Mechanism

  • Why don't the distributor's switchgear have the same capacity ?

  • The importance of having a dc ac voltage inside the distributor cells

  • DC loop drawings

  • AC loop drawings

  • The main rules for reading the schema of current circuits and the reasons that lead to their explosion.

  • Understand the general philosophy of closing, triping and interlock circuits.

  • Upstream & downstream interlocks

  • What is the working theory of anti-pumping relay and anti slam ?

  • Importance of trip circuit supervision in the early detection of circuit breaker faults.

  • The most important modifications in the schema before the distributor enters the service.

  • The most important modifications before energize

  • Introduction to 13.8KV ABB SwitchGear

  • The Importance of Automatic Changeover Switching Equipment ACSE

  • (Under Frequency  & Under Voltage)  Protection  Panel

  • philosophy of High Impedance  BusBar Protection Panel


Who this course is for:

  • - Electrical engineers
  • - Student at the Faculty of Engineering, Electrical Department
  • - Electrical technician