Testing Commissioning Protection GE Relays
What you'll learn
- Introduction to GE Multilin Protection Relays
- The EnerVista™ Launchpad software is a powerful toolset used for the complete support and management of Multilin products
- How to configure GE T60 relay ?
- The setting fault report and oscillography
- Build flex logic equation
- Trip circuit supervision configuration
- Test GE T60 differential relay by use advance differential module of omicron
- Automatic test by use PTL of omicron
- Introduction to GE L90 line differential distance protection
- Test GE L90 by use advance distance module of omicron
- Test GE L90 by use advance distance module of FREJA
- How use protection test library PTL of OMICRON ?
- Introduction to distance communication scheme
- How test direct under reach transfer trip DUTT ?
- How test permissive under reach transfer trip PUTT ?
- How test permissive over reach transfer trip POTT ?
- How test blocking scheme ?
- The importance of weak infeed protection
- Introduction to power swing phenomena
- How test power swing block and trip ?
- How test VT fuse fail function ?
- The importance of switch onto fault
- The importance of adjust setting of auto re closure
- How test auto re-closure shot ?
- How test circuit breaker fail protection ?
- Adjust line differential setting
- How test line differential protection ?
Requirements
- The basic electrical principles
Description
Dear fellows,
This is the most comprehensive online training of Testing Commissioning GE Relays . Here you will learn all thing about test GE T60 and GE L90 Relay
This course will give you an appreciation of how to commissioning this type of Protection Relays
Topics that we will talk about in the course :-
Introduction to GE Multilin Protection Relays
The EnerVista™ Launchpad software is a powerful toolset used for the complete support and management of Multilin products
How to configure GE T60 relay ?
The setting fault report and oscillography
Build flex logic equation
Trip circuit supervision configuration
Test GE T60 differential relay by use advance differential module of omicron
Automatic test by use PTL of omicron
Introduction to GE L90 line differential distance protection
Test GE L90 by use advance distance module of omicron
Test GE L90 by use advance distance module of FREJA
How use protection test library PTL of OMICRON ?
Introduction to distance communication scheme
How test direct under reach transfer trip DUTT ?
How test permissive under reach transfer trip PUTT ?
How test permissive over reach transfer trip POTT ?
How test blocking scheme ?
The importance of weak infeed protection
Introduction to power swing phenomena
How test power swing block and trip ?
How test VT fuse fail function ?
The importance of switch onto fault
The importance of adjust setting of auto re closure
How test auto re-closure shot ?
How test circuit breaker fail protection ?
Adjust line differential setting
How test line differential protection ?
Who this course is for:
- Anyone interested in electrical engineering
- Electrical undergraduates
- Electrical graduates
- Workers in the electrical power utility
Instructor
Hello,
I'm Osama Abdel Aziz
Electrical Power Systems Engineer
I Have
Bachelor of Degree in Electrical Power and Machines Engineering
i am work naw as protection enginner in EETC company
I share with you my academic and practical experience
I I find a real joy in teaching :).
Choosing an interesting and challenging field such as electrical engineering is a blessing and a gift I'm grateful For
Excellent knowledge and delivering the theory and practical concept with such an ease.
Trainer possesses strong competency in power plant and substation secondary system, scheme like busbar protection, breaker failure protection, substation automation, transformer differential, substation schemes lines/transformer/reactor/busbar, testing & commissioning of relays, scheme testing, testing of GIS/AIS substation equipment, testing of generator protection, on site trainings.