Udemy
Turn what you know into an opportunity and reach millions around the world.
Learn More
Your cart is empty.
Keep shopping
Defense Cybersecurity & IT Architecture
New
121 students

Defense Cybersecurity & IT Architecture

Master DoD Zero Trust, CMMC, and NIST baselines through practical architecture to secure enterprise defense ATOs.
Last updated 9/2026
English
English [Auto],

What you'll learn

  • Deconstruct statutory federal compliance hierarchies to map NIST SP 800-53 controls directly to DISA STIG parameters.
  • Architect isolated enclaves and cross-domain solution pipelines using hardware data diodes for classified systems.
  • Scope defensible CMMC 2.0 Level 2 and Level 3 assessment boundaries to safeguard Controlled Unclassified Information.
  • Calculate Supplier Performance Risk System scores and assemble audit-ready objective evidence packages for C3PAO audits.
  • Deploy the DoD Zero Trust Strategy across seven architectural pillars to satisfy mandatory FY2027 Target Level requirements.
  • Engineer software-defined micro-segmentation policies using identity tags to restrict east-west adversary lateral movement.
  • Implement Purdue Model Level 3.5 Industrial DMZs to isolate operational technology from corporate network intrusions.
  • Operationalize MITRE ATT&CK for Enterprise and ICS to build threat-informed detection engineering pipelines.
  • Execute compliant cyber incident response workflows satisfying strict DFARS 72-hour DC3 reporting mandates.
  • Build machine-readable Software Bills of Materials and continuous monitoring pipelines using DISA ACAS and SCAP.

Course content

6 sections • 35 lectures • 3h 18m total length
  • Regulatory Stack Harmonization: FISMA, RMF, CMMC, DISA STIGs, and CNSSI 12536:52

    **How do federal cybersecurity frameworks interlock across defense systems?**

    Federal mandates form a binding statutory hierarchy descending from FISMA and OMB Circular A-130 down to technical DISA STIG parameters and CNSSI 1253 classified overlays. This regulatory alignment bridges high-level statutory requirements with automated, machine-level configuration benchmarks across military enclaves.

    Core concepts covered:

    - Deconstruct statutory authority flow from federal statutes to technical DISA STIG baseline configurations

    - Ingest continuous telemetry into DHS CyberScope to eliminate point-in-time FISMA reporting overhead

    - Accelerate defense contract approvals by harmonizing CMMC 2.0 tiers with NIST SP 800-171/172 standards

  • NIST SP 800-53 Rev. 5 Baselines and Impact Level Categorization5:12

    **How does FIPS 199 high-water mark categorization determine NIST SP 800-53 control allocation?**

    FIPS 199 evaluates potential mission impact across confidentiality, integrity, and availability independently, using the highest evaluated severity to establish the foundational system baseline. This categorization dictates control selection across low, moderate, and high baselines while driving DoD Cloud SRG Impact Level scoping.

    Core concepts covered:

    - Apply FIPS 199 high-water mark logic to establish defensible NIST SP 800-53 Rev. 5 baselines

    - Scale security architecture controls across DoD Cloud Computing SRG Impact Levels 2 through 6

    - Eliminate audit friction by defining unambiguous technical control parameters and CNSSI 1253 overlays

  • The Modern ATO Lifecycle: From Interim Approvals to Continuous ATO (cATO)6:02

    **What technical prerequisites are required to transition from a 3-year ATO to continuous ATO?**

    Continuous ATO (cATO) replaces triennial snapshot assessments with real-time risk assurance driven by continuous telemetry feeds, active threat hunting, and automated DevSecOps platform governance. Maintaining this authorization requires immediate automated rollback capabilities and real-time visibility into baseline configuration drift.

    Core concepts covered:

    - Construct automated CI/CD compliance gates using static, dynamic, and containerized vulnerability scans

    - Engineer actionable POA&M workflows to eliminate Category I findings within strict 30-day windows

    - Minimize operational mission downtime and audit penalties by avoiding expired Interim ATO constraints

  • Classification Enclaves and Cross-Domain Boundary Architecture4:45

    **How do hardware data diodes enforce unidirectional boundary isolation between classification enclaves?**

    Hardware data diodes utilize physical LED transmitters and photodiode receivers to guarantee unidirectional data flow at the physical layer, completely eliminating return paths for data exfiltration or reverse command execution. This physical hardware enforcement isolates high-to-low and low-to-high networks according to strict NCDSMO security baselines.

    Core concepts covered:

    - Segregate defense network domains across NIPRNet, SIPRNet, and JWICS classification boundaries

    - Deploy hardware data diodes and NCDSMO-accredited Cross-Domain Solutions for secure enclave transit

    - Prevent costly national security data spillages by threat modeling physical and logical air-gap fallacies

  • Defense Security Governance: Roles, Responsibilities, and RMF Friction Points5:48

    **How does RMF Step 0 Prepare eliminate delivery friction between engineering leads and Authorizing Officials?**

    Executing RMF Step 0 during initial system design identifies classification boundaries, pre-approved cloud platforms, and security overlays before application code or infrastructure is provisioned. Early stakeholder alignment prevents late-stage architectural rework and aligns development velocity with formal authorization requirements.

    Core concepts covered:

    - Define clear RACI governance boundaries aligning Authorizing Officials, ISSMs, ISSOs, and system owners

    - Integrate RMF Step 0 Prepare workflows into system inception to avoid costly late-lifecycle redesigns

    - Translate technical CVE vulnerability metrics into actionable mission impact narratives during AO briefings

  • Knowledge Check

Requirements

  • Professional experience in enterprise networking, systems engineering, or technical information security administration.
  • Familiarity with foundational risk frameworks (such as NIST SP 800-37 or ISO 27001) is advantageous but not strictly mandatory.
  • Understanding of basic virtualization, cloud architecture, and corporate operating system administration.

Description

“This course contains the use of artificial intelligence.”


Defense contractors and federal systems integrators face existential operational risks: multi-year Authority to Operate (ATO) bottlenecks, debilitating assessment failures under CMMC 2.0, and targeted living-off-the-land intrusions from nation-state actors like Volt Typhoon. A single negative Supplier Performance Risk System (SPRS) score or missed 72-hour incident reporting window under DFARS 252.204-7012 can instantly disqualify an organization from critical defense procurement awards.


This enterprise-grade curriculum delivers a consulting-level deconstruction of defense cybersecurity architecture, compliance engineering, and operational survivability. Structured as an Executive Architecture Briefing, the course moves beyond passive checklist memorization into active systems engineering. Learners analyze production-ready reference topologies, cross-domain solutions, and software-defined micro-segmentation models designed for national security systems and mission-critical cloud enclaves.


**Key Architectural Capabilities Acquired:**

- Master the statutory federal regulatory hierarchy across FISMA, RMF, NIST SP 800-53 Rev. 5, and CNSSI 1253.

- Architect defensible CMMC 2.0 Level 2 and Level 3 boundaries to protect Controlled Unclassified Information.

- Deploy DoD Zero Trust Strategy reference baselines to satisfy mandatory FY2027 Target Level requirements.

- Engineer Industrial DMZs (Level 3.5) and hardware unidirectional data diodes using NIST SP 800-82 Rev. 3.

- Implement continuous monitoring pipelines using DISA STIGs, SCAP automation, and ACAS scanning.


**Frequently Asked Questions**


**What is Continuous Authority to Operate (cATO) in DoD environments?**

Continuous Authority to Operate (cATO) replaces traditional static three-year assessment cadences with automated, real-time security assurance. Operating a valid cATO requires Authorizing Official-approved DevSecOps reference pipelines, continuous automated endpoint and container telemetry feeds, active continuous threat hunting teams, and immediate automated rollback mechanisms to prevent baseline configuration drift.


**How does NIST SP 800-171 differ from NIST SP 800-172 under CMMC 2.0?**

NIST SP 800-171 establishes 110 foundational practices across 14 families required for CMMC Level 2 to safeguard Controlled Unclassified Information. NIST SP 800-172 introduces 24 enhanced, high-assurance security practices required for CMMC Level 3, specifically designed to restrict lateral movement, contain blast radiuses, and neutralize Advanced Persistent Threats.


**What are the primary pillars of the DoD Zero Trust Strategy?**

The DoD Zero Trust Strategy organizes technical security around seven synchronized pillars: User, Device, Network and Environment, Application and Workload, Data, Visibility and Analytics, and Automation and Orchestration. Defending against modern threats requires implementing 91 specific Target Level capabilities across all seven pillars before the FY2027 federal deadline.


Updated for the 2025/2026 defense acquisition and regulatory landscape, this curriculum provides actionable engineering methodologies to ensure contractual compliance and operational survivability across hybrid enterprise architectures.



Who this course is for:

  • Enterprise cybersecurity architects and systems engineers designing DoD and defense industrial base enclaves.
  • Information System Security Managers (ISSMs) and Officers (ISSOs) preparing for RMF authorizations and C3PAO audits.
  • Defense contractor IT leaders and compliance directors resolving SPRS deficiencies and DFARS 252.204-7012 mandates.
  • Industrial control systems (ICS/SCADA) engineers protecting operational technology in defense manufacturing plants.